ASTM D Pull Off Test Standard – Free download as PDF File .pdf), Text File .txt) or read online for free. Tensile_adhesion ASTM D – Download as PDF File .pdf), Text File .txt) or read online. SSPC-SP · Adhesion-ASTM-De Tensile (pull- off) adhesion testing (ASTM D ) is becoming a more widely specified testing . ASTM A/AM Steel, Sheet and Strip, Heavy-Thickness Coils, Hot- Rolled, Carbon, Commercial, Drawing, Structural, High-Strength Low-Alloy.

Author: Faunos Zulkizil
Country: Saint Lucia
Language: English (Spanish)
Genre: Software
Published (Last): 20 December 2004
Pages: 480
PDF File Size: 5.24 Mb
ePub File Size: 18.81 Mb
ISBN: 952-6-92301-152-7
Downloads: 5526
Price: Free* [*Free Regsitration Required]
Uploader: Nikosho

Results obtained by each test method may give different results.

This test method maximizes tensile stress as compared to the shear stress applied by other methods, such as scratch or knife adhesion, and results may not be comparable. This service is not available if you are a URL user where you do not log in with an email address.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but 09d1 not provided as part of the standard. A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition.

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

Historical Version s – view previous versions of standard. Combining values from the two systems may result in non-conformance with the standard.

Subscription – always available and updated A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition. Therefore, when a series of results will be compared with one another or used for statistical analysis, the type of apparatus, substrate, test procedures, glue type, and if scoring is used should be the same for the pulls considered. Depending on the radius xstm the surface, the results could have greater variability with lower values and averages.

This test method serves as a means for uniformly preparing and testing coated surfaces, and evaluating and reporting the results. Link to Active This link will always route to the current Active version of the standard. Note 2—Method A, which appeared in previous versions of this standard, has been eliminated as its main use is for testing on concrete substrates see Test Method D Measurements f4541 limited by the strength of adhesion bonds between the loading fixture and the specimen surface or the cohesive strengths of the adhesive, coating layers, and substrate.

TOP Related Articles  ROSAI AND ACKERMANS SURGICAL PATHOLOGY 10TH EDITION PDF

Failure will f4541 along the weakest plane within the system comprised of the test fixture, adhesive, coating system, and substrate, and will be exposed by the fracture surface. The moment new editions astmm the standards you monitor are released, changes are made, or appendixes are published, you will be alerted by email.

The procedure in this standard was developed for use on flat surfaces. This ensures that you are always up-to-date and saves you both time and money. Read more about subscriptions. Monitoring Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work. Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work.

Webprint Printed and bound. The benefits of a subscription: It is imperative to identify the test method used when reporting results. Measurements are limited by the strength of adhesive bonds between the loading fixture and the specimen surface or the cohesive strengths of the glue, coating layers, and substrate.

This includes change in glue, load fixture size, substrate coating cure time, pull rate, environmental conditions, if the coating is scored, or using a different device.

This test method maximizes tensile stress as compared to the shear stress applied by other methods, such as scratch or knife adhesion, and results may not be comparable. Results should only be assessed for each test method and not be compared with other d4514. NOK 1 ,00 excl. This test method is applicable to any portable apparatus meeting 09s1 requirements for determining the pull-off strength of a coating in this standard see Annexes.

Pull-off strength of coatings from concrete is described in Test Method D This test offers two test protocols. There are five instrument types, identified as Test Methods B-F. They are capable of applying a concentric load and counter load to a single surface so that coatings can be tested even though only one side is accessible.

It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use. Method A, which appeared in previous versions of this standard, has been eliminated as its main use is for testing on concrete substrates see Test Method D It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

TOP Related Articles  BHARAT EK KHOJ PDF

Fracture will occur along the weakest plane within the system comprised d441 the test fixture, glue, coating system, and substrate, and will be exposed by the fracture surface. You need to log in before adding standards to the monitoring service.

There are five instrument types, identified as Test Methods B-F. Pull-off strength of coatings from concrete is described in Test Method D Techstreet standards in subscription. The procedure in this standard was developed for metal substrates, but may be appropriate for other rigid substrates such as plastic and wood. Results obtained by each test method may give different results.

Protocol 1 test to fracture determines the greatest perpendicular force in tension that a surface area can bear before a plug of material is detached. Start Webshop Product catalog Product presentation. Active view current version of standard. Results should only be assessed for each test method and not be compared with other instruments. It is imperative to identify the test method used when reporting results.

ASTM D4541:09e1

Link to Active This link will always 90e1 to the current Active version of the standard. Note 1—The procedure in this standard was developed for metal substrates, but may be appropriate for other rigid substrates such as plastic and wood. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.