INTERZINC 315 PDF

Interzinc B. Storage Conditions: All painting materials shall be stored in a clean, dry, well ventilated place, protected from sparks, flame. A three component, metallic, zinc rich epoxy primer which passes Slip B coefficient. Interzinc B complies with SSPC Paint 20 and contains minimum 80%. Interzinc Call for Price. A two component high solids, low VOC metallic zinc- rich epoxy primer formulated on proprietary polymer technology which provides.

Author: Akijar Misar
Country: Kuwait
Language: English (Spanish)
Genre: Automotive
Published (Last): 23 October 2017
Pages: 283
PDF File Size: 11.28 Mb
ePub File Size: 11.76 Mb
ISBN: 426-1-42993-618-3
Downloads: 87655
Price: Free* [*Free Regsitration Required]
Uploader: Tamuro

All batch number, product identification and quantities shall be recorded on appropriate QC documents. Store and dispose of hazardous materials, and materials contaminated by hazardous materials, in accordance with requirements of local authorities having jurisdiction. Apply material at the required dry film thickness.

For each finish product specified, two samples representing actual product, color, and finish. Deliver materials in manufacturer’s original, sealed, undamaged container with identification label intact. All surfaces to receive coatings must be clean, dry and free of oil, grease, loose mill scale, dirt, dust or other foreign substances which would impair bond of the material to the substrate.

A copy of the transport document and manufacturers conformance certificate shall be attached to the material delivery QC form. If necessary for job schedule, the General Contractor shall provide enclosures and heat to maintain proper temperatures and humidity levels in the application areas.

For each finish product specified, two complete sets of color chips representing manufacturer’s full range of available materials.

Interzinc 315B

Submit manufacturer documentation that the fireproofing product complies with the specified contract requirements. Information must demonstrate equivalence of product and performance to the interinc material and complete systems. Moderate sulpher diuoxide levels. Do not commence application of coatings until the contractor, applicator and inspector have examined the surfaces to receive Work in this section, and determined that the surfaces are acceptable to receive the specified materials.

TOP Related Articles  SHARP PN E421 PDF

Substrate and air temperature shall be in accordance with the manufacturers 3155. Interior chemical processing areas and swimming pools. Clean substrate free of dust, dirt, grease or other foreign substances that would impair the bond of the coating. Once agreed upon in writing it serves as a guide for the finished work.

Regional Materials- 20 percent extracted, processed and manufactured regionally: To be selected by Architect from manufacturer’s full range of available colors. Interior environment with high humidity and exposure to air pollution.

Coating will be a complete system from a single source consisting of primer and topcoat. Commencement of application is acceptance of substrate. Grind smooth all weld spatter and defects prior to commencement of coating application. Pipes, ducts, conduits, hangers and supports, equipment, and equipment enclosures exposed to view in all rooms and spaces.

When deciding on the extent of the mock-up, consider all the major different types of work on the project. If this location falls within a mile radius of the project interzzinc, then Interchar can contribute to earning Materials and Resources Credit 5.

The relative humidity of the application area shall not exceed a maximum of 85 percent for 24 hours interznc, during and 24 hours after the application of the material. Maintain environmental conditions temperature, humidity, and ventilation within limits recommended by manufacturer for optimum results.

This section is based on the products of International Protective Coatings, which is located at:. Submit applicators current certification as a manufacturer trained and approved applicator.

TOP Related Articles  HP 3314A PDF

Steel substrate temperature shall be a minimum of 5 deg F 3 deg C above the dew point of the surrounding air for a period of 24 hours prior and during the application of the material. Moderate Atmosphere Applications – Industrial and coastal areas.

Interzinc – A k i r a

Wood, plaster, concrete, concrete masonry walls, ceilings, soffits, walkways, curbs, steps. Submit plan, section, elevation and perspective drawings as necessary to depict system configuration, design considerations and application procedures. Before proceeding with the work, the applicator will apply the primer and finish coat to a representative substrate section of square feet in size.

The Manufacturer’s quality management system must be assessed and registered by an independent registrar as conforming to the requirements of ISO Temporary protection and heat shall be maintained at this minimum temperature for 24 hours before, during and 24 hours after material application.

Interzinc | Litnobiles

Coordinate with Section and Contract Drawings for all Moderate Atmosphere areas of the project. Apply approved primer to properly cleaned substrate in accordance with manufacturer’s application instructions. The following is one example of how a mock-up on a large project might be specified.

Provide ventilation in areas to receive work of this section during application and minimum 24 hours after application. International Protective Coatings is the leading supplier of high performance Protective Coatings and forms part of Akzo Nobel, a market driven, technology based company specializing in Coatings, Chemicals and Pharmaceuticals.